matthias-1982
Goto Top

Platte online schalten bei RAID

Hallo
Wir haben eine Adaptec Karte 2100S. Jetzt ist eine Platte ausgefallen oder offline.
Wie kann ich jetzt diese Platte wieder online schalten.
Muss ich dazu im RAID BIOS auf den Menüpunkt rebuild drücken?

Gruss

Content-Key: 21717

Url: https://administrator.de/contentid/21717

Ausgedruckt am: 28.03.2024 um 16:03 Uhr

Mitglied: BartSimpson
BartSimpson 19.12.2005 um 17:32:48 Uhr
Goto Top
schau mal hier rein(steht auf der Adaptec Webseite:
How to replace a failed array drive on the 2100s, 3200s, 3400s RAID Controller.
Question
One of the array disks has failed in the RAID. What is the process or step-by-step procedure to replace the failed disk drive?

This information applies to the following product(s):

-Adaptec SCSI RAID-2100S,
-Adaptec SCSI RAID-2110S,
-Adaptec SCSI RAID-3200S,
-Adaptec SCSI RAID-3210S,
-Adaptec SCSI RAID-3400S,
-Adaptec SCSI RAID-3410S,
-Adaptec ATA RAID-2400S,

This information applies to the following operating system(s):

-This information is not operating system specific.
Answer
The process steps for replacing a failed RAID-1 or RAID-5 array drive are as follows:

Using SMOR Configuration Utility to replace the failed hard disk drive.

1. Remove and replace the failed hard disk drive according to the procedure in the computer hardware documentation. The drive must be set to the same SCSI ID as the originally failed drive. The drive must also be the same size or larger. If the drive is not, then it will not allow the RAID to be rebuilt.

2. Boot the system selecting the Ctrl+A to enter the SMOR Configuration Utility option.

3. On the left side highlight the Array icon.

4. Hold down the Alt key and press the 'R' key to see vertical RAID menu.

5. Select the Rebuild option to start the process to reconstruct the replaced drive from the existing good members (drives) in the array.


Using the Storage Manager Pro software to replace the failed hard disk drive.

1. Replace the hard disk drive according to the procedures in your hardware documentation.

2. Boot into the Operating System.

3. Start the Storage manager Pro software.

4. Select the local system icon and select Open System to display the array information.

5. Choose the Logical Configuration View in Storage Manager Pro.

6. Double click the array group icon to open the Array Group Information window.

7. Click Rebuild in the Array Group Information window to start the Rebuild process.

Note: The drive will display a flag to indicate that the rebuild process operation has started. The percentage of completion is displayed until the rebuild is completed.
Mitglied: Matthias-1982
Matthias-1982 21.12.2005 um 09:53:01 Uhr
Goto Top
Vielen Dank